Laserfiche WebLink
CABARRUS COUNTY 2012 APPRAISAL MANUAL <br />make the lot buildable using alternative systems or proprietary systems. <br />of septic systems and a general estimate of their average cost. <br />Systems that can be approved by the local Health Department: <br />System Average Cost 3 BR <br />Conventional Gravity System $ 4,000 <br />Low Pressure System $ 6,000 <br />Drip System $28,000 <br />Pre - treatment Drip System $40,000 <br />Systems that can be approved by the State of North Carolina: <br />System Average Cost 3 BR <br />Pre - treatment Surface Drip System $45,000 <br />(Requires 2 acres or more) <br />Land Model 04 <br />The following is a list of various types <br />Soil Depth Requirement <br />36 inches of suitable soil <br />24 inches of suitable soil <br />18 inches of suitable soil <br />As little as 12 inches of suitable soil <br />Soil Depth Requirement <br />As little as 6 inches of suitable soil <br />Adjustments for Acreage Requiring Non - conventional Septic Systems: (NCSS) <br />For the area found unsuitable calculate an adjustment to the nearest 5% that will deduct the following <br />values from the subject parcel: <br />Suitable for Conventional System <br />No adjustment <br />Low Pressure System Required <br />$ 2,000 <br />Drip System Required <br />$24,000 <br />Pre - treatment Drip System Required <br />$36,000 <br />Pre - treatment Surface Drip System Required <br />$41,000 <br />Once the septic system has been installed this adjustment is to be removed. <br />Example 1: A 10 acre parcel has been tested and approved for a drip system. Divide the total land value, say <br />$116,000 by the Drip System adjustment ($24,000/$116,000 = 20.68% or -20% NCSS added to the existing topo <br />adjustment. Note the amount of NCSS adjustment in the land line note field so that it can be removed once <br />the septic system has been installed. <br />[0120] [LDR ] [ 620] [ ] [1.160] [4] [ .80] [ +00 +00 +00- 20 +00][RP] [ 10000.00] [ 10.000] [AC] [ -20 NCSS] <br />Adjustments for Acreage Unsuitable for Septic when sewer is not available: (PERK) <br />No Suitable System Available -50% added to the TOPO adjustment <br />Found Unsuitable in the Past -20% added to the TOPO adjustment <br />(Alternative Systems Unknown) (Not to exceed $24,000 per 10 ac tested) <br />Adjustments will only be applied to the acreage that has been tested. Perk adjustments require some subjective <br />opinions from the appraiser; if a parcel has had substantial adjustment for topo applied due to certain areas being <br />deemed unbuildable or due to the existence of flood plane on the property, then perk test for those areas need <br />not be considered as the appropriate adjustments have already been made. The following examples are to be <br />used by the appraiser as guidance in making adjustments for perk rejections. <br />Example 1 - 10 ac with 1 approved site and 9 ac found to be unsuitable: If a parcel is 10 acres or less and <br />has one building site approved for a conventional system even if other sites were rejected then the highest and <br />best use of the parcel is a large building site and no Perk adjustment is necessary. <br />A 10 acre parcel has been tested and approved for 1 building site; no perk adjustment is needed even if other <br />sites were rejected. <br />[0120] [LDR ] [ 620] [ ] [1.160] [4] [ .80] [ +00 +00 +00 +00 +00][RP] [ 10000.00] [ 10.000] [AC] [ ] <br />Cabarrus County — 2012 Revaluation LAND APPRAISAL PROCEDURES 4- 27 <br />Attac1W9nn1imber 6 <br />G -3 Page 320 <br />