Laserfiche WebLink
EDISON FOARD <br />PC Box 19888 <br />Charlotte, INC 28219.0888 <br />Ph: (704)329-8000 <br />RFI <br />To: Paul Bielicki RFI #: 177 <br />Moseley Architects Date: 3/30/2017 <br />11430 North Community House Job: 16-2711 Kannapolis Middle School <br />Road Phone: <br />Charlotte, NC 28277 <br />Ph: 704-540-3755 Fax: 704-540-3754 <br />CC: <br />Subject: Waters Up From E234 <br />Drawing: BD -P4 (PCO 002) Spec Section: <br />Cost Impact: TBD Schedule Impact: TBD <br />Request: Date Required: 4/3/2017 <br />Please provide more information as to the intent of the 2 water lines. Are they to provide water to a teacher's station in the science <br />room above? <br />Requested by: Jerry Anderson <br />Edison Foard Inc <br />Response: <br />The water distribution to each science classroom is to be isolated on dedicated hot water <br />(HW) and cold water (CW) distribution branches. These dedicated branches are to include <br />a solenoid valve interlocked with an emergency shut-off switch that controls water to that <br />science classroom. In the area of "8th Grade Science E234" there are two dedicated HW <br />& CW branches with solenoid control. One set is for "8th Grade Science E234" and the <br />second set of HW & CW is for "7th Grade Science C143" directly above. <br />Ron Deese <br />Optima Engineering <br />April 5, 2017 <br />Answered by <br />Company Date <br />AtRageidnof rImber 3 `.n <br />F-7 Page 158 <br />