Laserfiche WebLink
PROJECT NAME <br />APPLICATION FOR NON -DISCHARGE PERMIT <br />GRAVITY SEWER MAIN EXTENSION <br />CHARLOTTE - WATER <br />BILLINGS PROPERTY <br />CHARLOTTE WATER PROJECT NO.: 100-22-596 S <br />PROJECT TYPE: [NEW CONSTRUCTION ❑RELOCATION <br />OTHER <br />BASIN: <br />❑ MODIFICATION OF PERMIT NO <br />ROCKY RIVER <br />VOLUME OF WASTEWATER GENERATED BY THIS PROJECT: 10,660 GALLONS PER DAY BASED <br />ON <br />65 GAL/DAY/BR X [(23 UNITS X 4 BR/UNITS)+(24 UNITS X 3 BR/UNITS)] <br />135 GAL/DAY/MULTI-FAMILY UNIT X UNITS OR IS BASED ON <br />WASTEWATER TREATMENT PLANT RECEIVING WASTEWATER: <br />❑ McALPINE CR. (NC0024970) ❑ IRWIN CR. (NCO024945) ❑ McDOWELL CR. (NCO036277) <br />❑ SUGAR CR. (NCO024937) ❑ MALLARD CR. (NCO030210) d ROCKY RIVER (NC0036269) <br />NATURE OF WASTEWATER 100 % DOMESTIC % INDUSTRIAL <br />COMMERCIAL <br />OTHER <br />ORIGIN OF WASTEWATER [jSUBDIVISION ❑ COMMERCIAL <br />❑ SCHOOL ❑ INDUSTRIAL <br />❑ APARTMENTS/CONDO'S ❑ OTHER <br />LIST ANY PARAMETER AND ITS CONCENTRATION THAT WILL BE GREATER THAN NORMAL DOMESTIC LEVELS: <br />NONE <br />IF WASTEWATER IS NON -DOMESTIC, DESCRIBE LEVEL OF PRETREATMENT: <br />N /A <br />IF A PRETREATMENT PERMIT IS REQUIRED, HAS ONE BEEN ISSUED? ❑YES ❑NO dN/A <br />HAS ENGINEER DETERMINED THAT DOWNSTREAM SEWERS ARE CAPABLE TO HANDLE THIS FLOW? [iYES ❑ NO <br />PERMIT NO. FOR SEWERS IMMEDIATELY DOWNSTREAM 407-664 <br />PIPE DIAMETER OF SEWERS IMMEDIATELY DOWNSTREAM 8" <br />HAS ENGINEER ETERMINED THAT INC DEM AND CHARLOTTE WATER MINIMUM DESIGN STANDARDS ARE MET BY THIS <br />PROJECT? [YES ❑ NO <br />COMPLETE NAME AND ADDRESS OF ENGINEERING DESIGN FIRM: <br />LANDWORKS DESIGN GROUP, P.A. <br />1230 WEST MOREHEAD STREET, SUITE 304 <br />CHARLOTTE, NC 28208 <br />TELEPHONE 704 _ 841 _ 1604 <br />PROFESSIONAL ENGINEER'S CERTIFICATION: <br />I, STEVEN S. WILSON ATTEST THAT THIS APPLICATION FOR <br />BILLINGS PROPERTY HAS BEEN REVIEWED BY ME AND IS ACCURATE AND COMPLETE TO THE <br />BEST OF MY KNOWLEDGE. I FURTHER ATTEST THAT TO THE BEST OF MY KNOWLEDGE THE PROPOSED DESIGN HAS BEEN <br />PREPARED IN ACCORDANCE WITH THE APPLICABLE REGULATIONS. ALTHOUGH CERTAIN PORTIONS OF THIS SUBMITTAL <br />PACKAGE MAY HAVE BEEN DEVELOPED BY OTHER PROFESSIONALS, INCLUSION OF THESE MATERIALS UNDER MY <br />SIGNATURE AND SEAL SIGNIFIES THAT I HAVE REVIEWED THIS MATERIAL AND HAVE JUDGED IT TO BE CONSISTENT WITH <br />THE PROPOSED DESIGN. <br />NORTH CAROLINA PROFESSIONAL ENGINEER'S SEAL, SIGNATURE, AND DATE: <br />CLT Water PERMIT NO. <br />PLANT FLOW ALLOCATION RECORDED BY: <br />PERMIT APPROVED BY: 1 <br />ISSUED <br />KERI B. CANTRELL, PhD, P.E., CHIEF ENGINEER <br />PROJECT NAME <br />APPLICATION FOR PERMIT FOR WATER MAIN EXTENSION <br />BILLINGS PROPERTY <br />CHARLOTTE WATER PROJECT NO.: 100-22-093 W <br />PROJECT DESCRIPTION: CONSISTS OF 410f LF OF 2", 2576f LF OF 8" WATER MAIN <br />2 FIRE HYDRANTS AND RELATED APPURTENANCES. <br />DESIGNED BY: FIRM: LANDWORKS DESIGN GROUP, P.A. <br />ENGINEER: STEVEN S. WILSON <br />ADDRESS: 1230 WEST MOREHEAD STREET, SUITE 304 <br />CHARLOTTE, N.C. 28208 <br />PHONE: (704) 841-1604 <br />THIS APPLICATION IS MADE UNDER AND IN FULL ACCORD WITH THE PROVISIONS OF CHAPTER 13OA-317 OF THE <br />NORTH CAROLINA GENERAL STATUTES, AND SUCH OTHER STATUTES AS RELATED TO PUBLIC WATER SYSTEMS. <br />CHARLOTTE WATER HAS BEEN GRANTED AUTHORITY TO ISSUE PERMITS FOR EXTENSION OF WATER MAINS <br />PURSUANT TO 15A NCAC 18C.1801. THE APPLICANT AGREES THAT NO SIGNIFICANT CHANGE OR DEVIATION <br />FROM THE PLANS AND SPECIFICATIONS APPROVED BY CHARLOTTE WATER WILL BE MADE WITHOUT THE WRITTEN <br />CONSENT AND APPROVAL OF CHARLOTTE WATER OR ITS AUTHORIZED REPRESENTATIVE. A PROFESSIONAL <br />ENGINEER LICENSED TO PRACTICE IN THE STATE OF NORTH CAROLINA SHALL SUBMIT A STATEMENT REFLECTING <br />THAT ADEQUATE OBSERVATIONS DURING AND UPON COMPLETION OF CONSTRUCTION INDICATES THAT <br />CONSTRUCTION WAS COMPLETED IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. <br />PERMIT NO <br />APPROVED: <br />R/W <br />, <br />KERI B. CANTRELL, PhD, P.E., CHIEF ENGINEER <br />CHARLOTTE WATER <br />5100 BROOKSHIRE BLVD. <br />CHARLOTTE, NORTH CAROLINA 28216 <br />50' TOTAL R/W <br />25' <br />19, <br />(MIN) <br />1'-0" 7'-0" 10'-0" <br />(TRAVEL LANE) <br />1.5% <br />(2.00% MAXI�- <br />2:1 CUT MAX. <br />3:1 FILL MAX. <br />PLANTING <br />STRIP <br />DATE <br />R/W <br />10' <br />19' —0" <br />(MIN) (MIN) (MIN) <br />10'-0" 7'-0" 5'-0" 1'-0° <br />(TRAVEL LANE) <br />1.5% <br />SLOPE 3/8" PER FT. 2.00% MAX) <br />1' <br />R 8, WM <br />3l 2:1 CUT MAX. <br />3'MIN. COVER <br />3:1 FILL MAX. <br />LOCAL RESIDENTIAL STREET SECTION <br />BILLINGS FARM ROAD <br />SKY VISTA DRIVE <br />SKYSCAPE DRIVE <br />SALEM RIDGE ROAD <br />8'- BOC 1 5' <br />BUILDING <br />NOTES: <br />1. NO PUBLIC WATER OR PUBLIC SANITARY SEWER MAIN CONSTRUCTION MAY TAKE PLACE ON THIS PROJECT UNTIL THE UTILITY <br />CONTRACTOR HAS REQUESTED, SCHEDULED AND ATTENDED A PRE -CONSTRUCTION CONFERENCE WITH THE CHARLOTTE WATER <br />CONSTRUCTION INSPECTOR ASSIGNED TO THE PROJECT. ANY WORK PERFORMED PRIOR TO THE PRE -CONSTRUCTION CONFERENCE <br />SHALL NOT BE ACCEPTED BY CHARLOTTE WATER AND SHALL BE REMOVED AND REPLACED WITH NEW MATERIALS. <br />2. APPROVAL FOR BACKFLOW PREVENTION REQUIREMENTS IS NOT PART OF THIS REVIEW. BACKFLOW PREVENTION REVIEW ENTAILS <br />PLAN SUBMITTAL VIA MECKLENBURG COUNTY'S CODE ENFORCEMENT PERMITTING PROCESS AT THE TIME OF APPLICATION FOR <br />BUILDING PERMITS. BACKFLOW PROGRAM REQUIREMENTS ARE AVAILABLE AT <br />http://charlottenc.gov/Water/Pages/BackflowConstructionGuidelines.aspx. PLEASE CONTACT MARK BULLINS AT 704-432-5800 FOR MORE <br />INFORMATION. <br />3. ANY REVISION TO THE SERVICE CONFIGURATIONS AND/OR METER LOCATIONS WILL REQUIRE A RESUBMITTAL TO BACKFLOW FOR <br />REVIEW. <br />4. CONSTRUCTION AND MATERIALS SHALL BE IN ACCORDANCE WITH CHARLOTTE WATER STANDARDS AND SPECIFICATIONS PER <br />WEBSITE AT WWW.CHARLOTTEWATER.ORG. <br />5. ALL CONTRACTORS WORKING ON CHARLOTTE WATER PROJECTS ARE REQUIRED TO OWN A COPY OF THE DESIGN MANUAL AND SHALL <br />KEEP A COPY ON THE JOB SITE AT ALL TIMES. <br />6. CONTRACTOR IS FULLY RESPONSIBLE FOR CONTACTING ALL APPROPRIATE PARTIES AND ASSURING THAT UTILITIES ARE LOCATED <br />PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. CALL NC811 AT 1-800-632-4949 OR 811 FOR UTILITY LOCATING SERVICES 72 <br />HOURS PRIOR TO COMMENCEMENT OF ANY WORK. CONTRACTOR SHALL VERIFY LOCATION AND DEPTH OF ALL EXISTING UTILITIES <br />PRIOR TO CONSTRUCTION. <br />7. IF THE PROPOSED WATER AND/OR SANITARY SEWER MAIN IS INSTALLED WITHIN 12" IN ANY DIRECTION (VERTICALLY OR <br />HORIZONTALLY) FROM NATURAL GAS MAINS, THE CONTRACTOR SHALL INFORM PIEDMONT NATURAL GAS COMPANY AT (704) 525-5585 <br />AND INFORM THEM. <br />8. SANITARY SEWER LATERAL LOCATIONS ARE APPROXIMATE AND ARE SUBJECT TO RELOCATION DUE TO FIELD CONDITIONS. <br />9. SANITARY SEWER LATERALS ARE TO BE INSTALLED AT A DEPTH NO GREATER THAN FIVE (5) FEET WHERE PRACTICAL AT THE <br />PROPERTY LINE UNLESS INDICATED ON THE PLANS TO BE INSTALLED AT "MINIMUM SLOPE". <br />10. MINIMUM COVER OF 36" FOR WATER MAINS. <br />11. DUCTILE IRON PIPE (RED BRASS FOR 2" WATER PIPE) REQUIRED FOR BOTH WATER AND SANITARY SEWER LINES IF THE FOLLOWING <br />CLEARANCES ARE NOT MET: <br />• WATER LINE CROSSING UNDER SEWER LINE (FOR ANY CLEARANCE) <br />• 18" VERTICAL FOR FOR WATER LINE INSTALLED ABOVE SEWER LINE. <br />• 10' HORIZONTAL SEPARATION FOR WATER LINE PARALLEL TO SEWER LINE (OR 18" VERTICAL SEPARATION IN SEPARATE DITCHES). <br />• FOR WATER LINES 12" CLEARANCE WITH STORM DRAINS, GAS MAINS, TELEPHONE DUCTS, AND UNDERGROUND CABLES. <br />12. RECORDED PLATS ARE REQUIRED FOR ACTIVATION OF WATER MAINS, EASEMENTS ARE NOT ACCEPTABLE. <br />13. ALL WATER MAINS AND SERVICES SHALL BE INSTALLED WITH SOLID COPPER 12-GAUGE TRACER WIRE, 30 MILS BLUE HDPE INSULATION. <br />CONDUCTIVITY TEST REQUIRED DURING FINAL INSPECTION. CONTRACTOR SHOULD PROVIDE ALL TEST EQUIPMENT. <br />14. ALL SEWER MAINS AND SERVICES SHALL BE INSTALLED WITH SOLID COPPER 12-GAUAGE TRACER WIRE, 30 MILS GREEN HDPE <br />INSULATION. CONDUCTIVITY TEST REQUIRED DURING FINAL INSPECTION. CONTRACTOR SHALL PROVIDE ALL TEST EQUIPMENT. <br />15. COMPLETE TRENCH BACKFILL SHALL BE IN PLACE 30 CALENDAR DAYS PRIOR TO SCHEDULING PVC PIPE MANDREL TESTING. <br />16. CURB AND GUTTER SHALL BE CONSTRUCTED PRIOR TO WATER MAIN INSTALLATION. <br />17. SEPARATE PLAN SUBMITTAL REQUIRED TO BACKFLOW PREVENTION FOR REVIEW / APPROVAL PERTAINING TO ANY APPLICABLE <br />BACKFLOW DEVICES. <br />18. WATER MAIN EXTENSIONS WITHOUT SERVICES SHALL INCLUDE AIR RELEASE AT ALL HIGH POINTS IN WATER MAINS OR EVERY 1000LF. <br />19. EXISTING MANHOLES MAY HAVE TO BE REPAIRED OR REPLACED, DEPENDING ON THE CONDITION, AS DETERMINED BY THE CHARLOTTE <br />WATER INSPECTOR. <br />20. ALL VALVE ASSEMBLIES SHALL BE COMPLETELY OUTSIDE OF ADA HANDICAP RAMPS. FIRE HYDRANTS SHALL BE COMPLETELY OUTSIDE <br />SIDEWALKS AND RAMPS. <br />21. NET 15WATER MAIN EASEMENT REQUIRED UNLESS APPROVED BY ENGINEER. <br />22. ANY NEW METERS OR IRRIGATION METERS INSTALLED/RELOCATED AFTER THE BACTERIAL AND PRESSURE TEST SHALL REQUIRE AN <br />ADDITIONAL BACTERIAL TEST. A CLT WATER INSPECTOR SHALL WITNESS THE TAP UNCOVERED UNDER STATIC CONDITIONS TO VERIFY <br />IF LEAKS ARE PRESENT. <br />23. ALL PROPOSED WATER METERS SHALL NOT BE INSTALLED IN DRIVEWAYS OR IN ADA RAMPS. <br />24. CLTWATER MANHOLE COVERS ARE NOT PERMITTED ON PRIVATE MANHOLES. <br />``/11111111,,� `,/111111111,1 <br />�.\A C A R <br />7� =� ° = SEAL rLandworkso* _* ;LLC-2930" *_ <br />°o <br />0 <br />Design Group, PA <br />Z. <br />!�NE�°`��p�' ����� CREATING SPACES TO LIVE, WORK AND PLAY <br />�� 1 S.i 11 � `,IO/16/Z3 ,00 <br />��� 01111,1 � 1� `,`, 1230 West Morehead Street, Suite 304 tel: 704-841-1604 <br />Charlotte, NC 28208 fax 704-841-1604 <br />CHARLOTTE <br />WAITER <br />APPROVED <br />��,_«&1_ 11 /14/2023 <br />Chris Saunders Date <br />CONSTRUCTION SHALL BE IN ACCORDANCE WITH <br />CHARLOTTE WATER STANDARD SPECIFICATIONS. <br />Page 36 <br />CONSTRUCTION SHALL BE IN ACCORDANCE WITH <br />CHARLOTTE WATER STANDARD SPECIFICATIONS. <br />