labeled with circuit number and function. These labels shall match the "as built" wiring schematic included <br />with the vehicle(s) at time of delivery. It is preferred that this panel be mounted on or near the bulkhead of <br />the patient compartment. It must have a closed, locking, well ventilated cabinet. Electrical cabinets which are <br />accessed through exterior ambulance doors are not acceptable due to the possibility of the introduction of <br />dirt, moisture, or other undesirable and potentially damaging agents. All circuit breakers, relays, flashers and <br />diodes shall be mounted on this panel and be easily accessible. <br />Does your bid comply? Yes _X_ No <br />Wiring Criteria (2) <br />Adjacent to the main power distribution board there shall be the electronic control module. This module shall <br />include four (4) etched trace "printed" circuits connected to the total electrical system by three (3) computer <br />type cables. This module shall direct low voltage switch commands from the front and rear control panels to <br />the relays on the main power distribution board. This module shall include a five - minute delay timer circuit <br />for patient compartment dome lights to function as checkout lights. Opening the rear or curbside doors with <br />the battery switch off shall activate this circuit. After five minutes the circuit shall automatically turn off the <br />dome lights. Cycling the left dome circuit switch will reactivate the circuit. This module shall be capable of an <br />upgrade to include, if specified, an automatic sequencer circuit for emergency lighting and /or a load manager <br />circuit to automatically "unload" non - critical lighting in the event of battery or charging system problems. <br />There shall be spare jumper cards supplied with the vehicle for the logic board; one (1) each for the five - <br />minute timer circuit and the sequencer /load manager circuits, if specified. <br />A six -inch service loop of wire or harness shall be provided at all electrical components, terminals, and <br />connection points. Circuit breakers shall be of the automatic reset type and designed specifically for each <br />circuit. One spare 15- ampere circuit breaker shall be provided for future use. All connections and terminals <br />provided shall comply with SAE J163, or J561 or J928 as applicable. <br />The main wiring harness for the module body shall be installed down the center of the patient compartment <br />ceiling. Each electrical circuit shall branch from the master harness as needed. There shall be no splices in this <br />harness. Each circuit wire shall run from the distribution panel to the fixture without a break or connection. <br />An access panel shall run the entire length of the center of the ceiling to simplify access to the "master" wiring <br />harness. A padded upholstery type material to prevent head injuries shall cover the access panel. This panel <br />shall be fastened to the ceiling with collared trim screws. Wiring runs accessed by removing interior cabinets <br />or portions thereof are not acceptable to the Purchaser. <br />30 <br />Attachment number 1 <br />F -2 Page 78 <br />