My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
AG 2012 02 20
CabarrusCountyDocuments
>
Public Meetings
>
Agendas
>
BOC
>
2012
>
AG 2012 02 20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2012 12:23:26 PM
Creation date
11/27/2017 11:07:30 AM
Metadata
Fields
Template:
Meeting Minutes
Doc Type
Agenda
Meeting Minutes - Date
2/20/2012
Board
Board of Commissioners
Meeting Type
Regular
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
253
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
curbside and rear entry doorsills. The side and rear thresholds shall be 6" minimum. To <br />improve threshold seal, strengthen the threshold and prevent equipment snags or tripping, <br />the side and rear thresholds will be fit with a 2 ❑ chamfer where the threshold meets the <br />floor. <br />Does your bid comply with "A" through "L "? Yes No_ <br />5.15 Hold -Open Devices <br />A. All compartment doors are to Suspa or equivalent dual action hold- opens. <br />B. The side entry door shall have a Suspa or equivalent hold open device. <br />C. The rear entry doors are to have FOUR (4) Cast Products Model C 10870-1 "Grabber" Door <br />Stays. <br />D. Compartment and access doors are to have separate "door open" warning indicator lights <br />installed on the front switch control panel. <br />Does your bid comply with "A" Through "D "? Yes No <br />5.16 Exterior Compartment Latching Mechanis <br />All compartments shall have a latching mechanism with the following characteristics: <br />A. The locking device shall be EBERHART/ TRIMARK ROTARY STYLE LATCHES. <br />B. All exterior compartments shall have Eberhart / TriMark automotive style handles with <br />rotary type latches. These rotary style locks shall lock on to a "NADER" type pin located <br />in each doorjamb. Nader pins shall be adjustable. Locking systems not using the above <br />style hardware will be unacceptable. <br />C. The module curbside and rear entry doors shall have Eberhart / TriMark automotive style <br />handles with rotary latches and "NADER" pins. These doors shall also have power door <br />locks tied into door locks on chassis. <br />D. All of the above latches must be installed with a corrosion barrier type gasket between latch <br />and door surfaces. C1052 zinc - plated steel connecting rods shall be used between the <br />paddle handle and the rotary latches. These rods shall be threaded at the latch end to allow <br />the door rod connector to be screwed onto the rod itself. The other end of the rod shall be a <br />formed eyelet incorporating a hole for the handle pin. This system shall conform to AMD <br />Standard 002. Systems using pulleys, cables, turnbuckles, or welded together components <br />are not acceptable, and will be rejected. No exceptions to the above requirements will be <br />allowed. <br />E. To reduce the probability of corrosion and oxidation around the paddle latch, the mounting <br />area will be treated with ECK. <br />Does your bid comply with "A" through "E "? Yes No <br />5.17 Exterior Storage Accommodations <br />The ambulance shall be equipped with exterior compartments as shown in the drawings at the <br />conclusion of this text. There shall be no more than a 3" dimension between door openings of <br />AttachAt number 1 <br />F -5 Page 122 <br />
The URL can be used to link to this page
Your browser does not support the video tag.