Laserfiche WebLink
26. CENTER WALL IN EACH RUN IS TO HAVE AN OPENING OF APPROX. <br /> 24w X 30h WITH GUILLOTINE TYPE DOOR TO ALLOW ANIMALS TO <br /> MOVE FROM INTERIOR SECTION OF RUN TO EXTERIOR SECTION. <br /> THE DOOR WILL BE EQUIPPED WITH A STEEL CABLE AND PULLEY <br /> MECHANISM TO ALLOW OPENING AND CLOSING FROM THE <br /> EXTERIOR WALKWAY. <br />27. ENTRANCE DOORS ARE TO BE SOLID CORE METAL CLAD DOORS <br /> WITH DOUBLE DEAD BOLT LOCKS. DOORS ARE TO BE EQUIPPED <br /> WITH SELF CLOSING MECHANISMS WHICH ALLOW THE DOORS TO <br /> BE POSITIONED IN AN OPEN POSITION. <br />28. INTERIOR DOORS IN HALL ARE TO BE OF ALUMINUM <br /> CONSTRUCTION WITH WINDOW IN EACH DOOR AT HEAD HEIGHT. <br /> THESE DOORS WILL BE SWINGING DOORS WITH RUBBER SEALS AT <br /> TOP, BOTTOM AND MIDDLE. A MECHANISM WILL BE PROVIDED TO <br /> POSITION THESE DOORS IN THE OPEN POSITION FOR CLEAN UP AND <br /> VENTILATION. <br />29. EACH RUN IS TO BE EQUIPPED WITH GATES ON THE INTERIOR AND <br /> EXTERIOR ENTRANCES TO EACH RUN. THE EXTERIOR GATES WILL <br /> BE EQUIPPED WITH A MECHANISM FOR THE PADLOCKING OF THE <br /> GATE. <br />30. ALL ENCLOSED ROOMS WILL HAVE FLOOR DRAINS AT CENTER <br /> WITH PROPER SLOPE OF FLOOR TO PROVIDE ADEQUATE DRAINAGE. <br />31. ACCESS TO HOT WATER TO BE PROVIDED AT TWO (2) LOCATIONS IN <br /> INSIDE HALLWAY AND TWO LOCATIONS ON OUTSIDE ALONG <br /> SOUTH SIDE OF BUILDING AND ONE (1) LOCATION IN THE CENTER <br /> OF THE NORTHERN OUTSIDE AREA. THE HOT WATER SYSTEM <br /> SHALL BE EQUIPPED WITH A TEMPERATURE CONTROL MECHANISM <br /> AT THE LOCATION WHERE IT COMES OFF THE HOT WATER HEATER. <br /> FREEZE PROTECTION FAUCETS SHALL BE PROVIDED. (SEE FLOOR <br /> PLAN FOR SUGGESTED LOCATIONS OF HOT WATER ACCESS). <br /> HEAT WILL BE PROVIDED FOR INTERIOR OF SHELTER AREA BY <br /> MOST ECONOMICAL MEANS POSSIBLE AFTER CONSIDERING THE <br /> TYPE AREA BEING SERVED. (IF HEATING METHOD PRECLUDES <br /> FORCED AIR AND AIR CONDITIONING IS RULED OUT- THEN CEILING <br /> FANS SHOULD BE INSTALLED IN THE INTERIOR HALLWAY AT <br /> LEAST EACH 12 FEET TO PROVIDE SOME MEANS OF AIR MOVEMENT <br /> TO HELP DRY FLOORS AFTER WASH DOWN AND PROVIDE <br /> IMPROVED VENTILATION DURING HOT <br /> <br /> <br />