Laserfiche WebLink
WEDDINGTON RD. <br /> This two lane road separates the commercial and residential parcels from <br />industrial. It is comparable to Poplar Tent Rd. in type, capacity and ADT as define~- <br />by NC Department of Transportation. The current design capacity is estimated at <br />10,600 trips/day. The 1991 ADT for Weddington Rd. is 2,300 which is at 22% capacity <br /> The traffic generations projected by the development for Weddington Rd. at 40:_ <br />will be approximately 6,544. These additional trips the capacity at design year 2020 <br />will be increased to 83%. Road improvements are indicated for this road system. T¢ <br />allow for the increase of future traffic increases, it is recommended that 10 feet o} <br />land be dedicated by the developer to the widen the link of Weddington Rd. contained-- <br />in the development for future construction of a third lane. At the time of the initia~ <br />development, turning lanes are indicated for access into the commercial and residentia <br />areas. -- <br /> It is also recommended that access be limited to two, instead of the proposed <br />four, points off this road.. This limitation ~vou]d not only mitigate accident rates and <br />to reduce the number of traffic movements. These would include Concord Farms Rd~_ <br />crossing the commercial portion into the residential area in addition to a similar access <br />on the east side. <br /> <br />CONCORD FARMS RD, <br /> There is no current ADT for this road between US29 and Weddington Rd. <br />However, it is being compared, for the purposes of this study, to Harris Rd. between <br />Poplar Tent Rd. and Ode]l School Rd. which has a design capacity od 9000, a I$90-- <br />ADT of 500 which is at 6% capacity (NCDOT). This road will carry approximately 80% <br />of all traffic generated by the development, allowing for those residents not employed <br />in the industrial area as well as those employees who are not residents. The projected_ <br />ADT for this road with the proposed development at build-out is 13,088. This <br />increases the capacity to 145% suggesting strong indications for road improvement. It <br />is recommended that this road be widened, resurfaced to accommodate heavier and more <br />frequent traffic and to be straightened where necessary. Again, timing is to be" <br />concurrent with development. <br /> <br />WESTSIDE BYPASS <br /> This alignment is planned to parallel Concord Farms Rd. on the east side. It <br />is strongly recommended that access be limited. Currently, the Propst development <br />plan indicated two access points with no fixed locations. These should be located to <br />provide access at a location that could be used as access to the prope~.ty on the <br />eastern side of the proposed alignment. <br /> The Westside Bypass will eventually connect US29 and Weddington Rd. This is <br />expected to reduce traffic on Weddington Rd. as employees come from/~o Charlotte. <br />It also has implications for traffic volumes on US29. <br /> <br /> It should also be noted that there are plans for major residential developments- <br />planned for both the east and west parcels adjoining the Propst property. These <br />subdivisions will also impact the traffic patterns and volumes of the road network. <br /> <br />CONCLUSIONS: <br /> The Department of Transportation will impose their minimum design standards on <br />the road system serving the Propst property which ~vill be determined after DOT <br />reviews the final plan. In addition to what will be specified by DOT, it is- <br />recommended that attention be given to the issues presented herein. <br /> <br /> <br />